DWD 301.07(14)(g)(g) Illumination of common use facilities shall be not less than 10 foot candles 30 inches above the floor. DWD 301.07(14)(h)(h) Public passageways, stairways, and exit doors shall be illuminated in accordance with the Wisconsin commercial building code. DWD 301.07(15)(a)(a) All rooms containing toilet facilities shall comply with the Wisconsin commercial building code, except that privies are not permitted. DWD 301.07(15)(c)(c) Urinals of the approved type shall be provided in toilets to be used by 10 or more males in the ratio of one per 40 males or fraction thereof. DWD 301.07 NoteNote: Par. (c) is amended eff. 1-1-2028 by CR 23-030 to read: DWD 301.07 Note(c) Urinals installed in accordance with the manufacturer’s specifications shall be provided in toilet facilities to be used by 10 or more males in the ratio of one per 25 males or fraction thereof.
DWD 301.07(15)(d)(d) Except in individual family units, separate toilet facilities for men and women shall be provided and all of the following apply: DWD 301.07(15)(d)1.1. Toilet facilities for men and women that are in the same building shall be separated by a solid wall from floor to roof or ceiling. DWD 301.07(15)(d)2.2. Toilet facilities shall be distinctly marked “men” and “women” in English and in the language of the persons expected to occupy the housing or marked with easily understood pictures or symbols. DWD 301.07(15)(e)(e) Where common use toilet facilities are provided, an adequate and accessible supply of toilet tissue with holders shall be furnished. DWD 301.07(15)(f)(f) All common use toilet facilities shall be well lighted and ventilated and shall be clean and sanitary. DWD 301.07(15)(g)(g) Toilet seats shall be of impervious material or shall be well painted or varnished. DWD 301.07(15)(h)(h) All living quarters and service buildings shall be provided with toilet facilities that are located within 200 feet of each living unit. DWD 301.07(16)(a)(a) Bathing and handwashing facilities shall be supplied with adequate hot and cold water under pressure and shall be provided for the use of all occupants. DWD 301.07(16)(b)(b) Bathing and handwashing facilities shall be clean and sanitary and located within 200 feet of each living unit. DWD 301.07 NoteNote: Par. (c) is amended eff. 1-1-2028 by CR 23-030 to read: DWD 301.07 Note(c) There shall be a minimum ratio of one showerhead per 8 occupants of a migrant labor camp.
DWD 301.07(16)(d)(d) Showerheads shall be spaced at least 3 feet apart with a minimum of 9 square feet of floor space per showerhead or shall be placed in a commercially available 30-inch shower stall that has an area of at least 6.25 square feet. DWD 301.07(16)(e)(e) Floors of showers shall be constructed of nonabsorbent, nonskid materials and sloped to properly constructed floor drains. DWD 301.07(16)(f)(f) If common use shower facilities for both sexes are located in the same building, the facilities shall be separated by a solid opaque and nonabsorbent wall extending from the floor to ceiling or roof, and shall be plainly designated “men” or “women” in English and in the language of the persons expected to occupy the housing or marked with easily understood pictures or symbols. DWD 301.07(16)(g)(g) Adequate dry dressing space shall be provided in common use shower facilities. DWD 301.07(16)(h)(h) Except in individual family units, separate shower facilities shall be provided for each sex. DWD 301.07(16)(i)(i) Each shower unit for women shall be enclosed as a separate compartment. DWD 301.07(16)(j)(j) Each shower compartment shall be supplemented by an individual dressing compartment. DWD 301.07(16)(L)(L) Mechanical or automatic washers that are supplied with adequate hot and cold water under pressure shall be provided for the use of all occupants in the ratio of one per 20 occupants. DWD 301.07(16)(p)(p) At least one laundry tray, tub, or sink shall be provided in each room that includes a washer. DWD 301.07(16)(r)(r) Dryers shall be provided for the use of all occupants in the ratio of one per 20 occupants. DWD 301.07(17)(a)(a) If workers or their families are permitted or required to cook in their individual unit, a space shall be provided and equipped for cooking and eating. The space shall be provided with all of the following: DWD 301.07(17)(a)3m.3m. A refrigerator maintained at 40 degrees Fahrenheit or lower and a freezer maintained at zero degrees Fahrenheit or lower. DWD 301.07(17)(a)4.4. A table and chairs or equivalent seating and eating arrangements that are commensurate with the capacity of the unit. DWD 301.07(17)(b)(b) If workers or their families are permitted or required to cook and eat in a common facility, a room or building separate from the sleeping facilities shall be provided for cooking and eating. The room or building shall be provided with all of the following: DWD 301.07(17)(b)1.1. Stoves with an oven in a ratio of one stove to 10 persons or one stove to 2 families. DWD 301.07(17)(b)3m.3m. A refrigerator maintained at 40 degrees Fahrenheit or lower and a freezer maintained at zero degrees Fahrenheit or lower. DWD 301.07(17)(b)4.4. Tables and chairs or equivalent seating adequate for the intended use of the facility. DWD 301.07(17)(c)(c) If central mess facilities are provided, the kitchen and mess hall shall be in proper proportion to the capacity of the housing and shall be separate from the sleeping quarters. DWD 301.07(17)(d)(d) Central mess facilities operated by or for the camp operator shall comply with all of the following: DWD 301.07(17)(d)1.1. The kitchen and dining room shall be separated from sleeping quarters and rooms containing toilet facilities. DWD 301.07(17)(d)3.3. Kitchen and dining room tables and chairs or benches shall be so constructed as to be easily kept clean. DWD 301.07(17)(d)5.5. Dishes and utensils shall be of nontarnishable materials, free from cracks and easily cleaned. DWD 301.07(17)(d)6.6. Cooking utensils shall be stored on racks or suspended on hooks at least 12 inches above the floor. DWD 301.07 NoteNote: The department recommends using a sweeping compound that lays the dust.
DWD 301.07(17)(d)8.8. The kitchen and dining room shall be scrubbed with hot soap suds or suitable detergent at least once a week. DWD 301.07 NoteNote: During rainy periods, the department recommends scrubbing more often than once a week.
DWD 301.07(17)(d)9.9. Dining tables shall be washed with soap or suitable detergent and water after each meal. DWD 301.07(17)(d)10.10. Handwashing facilities shall be provided in kitchens and shall include hot and cold water under pressure, soap and individual toweling for use by kitchen personnel only. DWD 301.07(17)(d)12.12. A sink with ample facilities for providing hot and cold water under pressure shall be provided for washing dishes and kitchen utensils. DWD 301.07(17)(d)13.13. All dishes and utensils shall be thoroughly scraped and shall be washed and scalded or disinfected. DWD 301.07(17)(d)15.15. All milk used shall either be adequately pasteurized, evaporated or powdered. DWD 301.07(17)(d)16.16. Perishable foods such as meats, milk, butter, eggs, and salads shall be kept under refrigeration not to exceed 40 degrees Fahrenheit. DWD 301.07(17)(d)17.17. Refrigerators shall be thoroughly washed with hot water and soap or suitable detergents at least once a week. DWD 301.07(17)(d)18.18. Nonperishable foods shall be stored in clean and rodent proof containers elevated above the floor. DWD 301.07(17)(d)19.19. The wall surface adjacent to cooking areas shall be of fire-resistant material and shall comply with the Wisconsin commercial building code. DWD 301.07(18)(a)(a) Durable, fly tight, rodent tight, and clean containers in good condition of a minimum capacity of 20 gallons, shall be provided adjacent to each housing unit for the storage of garbage and other refuse. DWD 301.07(18)(b)(b) Containers required under par. (a) shall be provided in a minimum ratio of 1 per 10 persons and shall be emptied when full, but not less than twice a week. DWD 301.07(18)(d)(d) The disposal of garbage and other refuse shall be in accordance with state and local law. DWD 301.07(19)(19) Insect and rodent control. Housing and facilities shall be free of insects, rodents and other vermin. DWD 301.07(20)(b)(b) Sleeping facilities shall consist of comfortable beds or bunks, and shall be provided with clean mattresses covered with a sanitized, waterproof material. DWD 301.07(20)(bm)(bm) Sleeping facilities shall be spaced no closer than 36 inches both laterally and end-to-end and shall be elevated at least 12 inches from the floor. DWD 301.07(20)(c)(c) Any bedding provided by the camp operator shall be clean and sanitary. DWD 301.07(20)(e)(e) The clear space above the top of the lower mattress of a bunk bed and the bottom of the upper deck shall be a minimum of 27 inches. DWD 301.07(20)(f)(f) The distance from the top of the upper mattress to the ceiling shall be a minimum of 36 inches. DWD 301.07(20)(g)(g) Sleeping facilities may not contain beds used for double occupancy except in family accommodations. DWD 301.07(21)(a)(a) All buildings shall be constructed and maintained in accordance with applicable state or local fire and safety laws. DWD 301.07(21)(b)(b) Any family housing and housing units for less than 10 persons that are of one-story construction shall have 2 means of escape.